Configuration of the CommServer UA to wrap OPC DA server is a straightforward process, which can be done in 5 steps:

  1. Connect to OPC server using OPC Viewer.

  2. Create online subscription in OPC Viewer.

  3. Export address space to a dictionary file using OPC Viewer.

  4. Create new project in UA Address Space Model Designer and choose configuration plugin.

  5. Import OPC DA address space and build the model.

Note Note

OPC Viewer is a free software tool that is very useful for developers, testers, integrators, and other users of the OPC. OPC Viewer has the functionality of saving the current configuration in a file called session. UA Address Space Model Designer is a user-friendly tool supporting all aspects of the model designing process.

Note Note

Both OPC Viewer and UA Address Space Model Designer are included in:

  • CommServerUA package which can be downloaded from here.

  • UA Address Space Model Designer package which can be downloaded from here.

In this walkthrough, the CommServerUA package is used.

Prerequisites
  • CommServer is installed (CommServer can be downloaded from here)

  • CommServerUA is installed (CommServerUA can be downloaded from here)

Note Note

Before installation of the CommServerUA make sure that the following software is installed on your computer:

  • Microsoft .NET Framework 3.5 Redistributables

  • OPC Core Components

  • Windows 2000/Windows XP/Windows Vista/Windows 7

1. Connect to OPC server using OPC Viewer
  1. To start OPC Viewer, select:

    Start Menu -> All Programs -> CAS -> CommServerUA -> OPC Viewer (OPC DA Classic Client)

    The main window appears.

  2. To connect to OPC Server, click “Browse network” icon ( Browse Network Icon ) in the menu. The Select Server window appears (Figure 1); select OPC Server from a local or remote computer (e.g. CAS.CommServer.OPC.Da.Server):

    OPCViewer Select Server Window
    Figure 1: OPC Viewer – Select Server window

    Select the computer and check what servers are available (to check available servers click on “+” next to the computer name).

    Note Note

    Remember to configure DCOM properly before connecting to the other computer.

    The added OPC server is not connected (OPCServer Not Connected Icon)

    You can add a multiple OPC server to the configuration. It can be also the same OPC server or any other OPC server.

    OPCViewer MultipleOPCServers
    Figure 2: OPC Viewer – multiple OPC servers
  3. Click the right mouse button on the added server and select “Connect” from the context menu or click “Connect to Server” icon ( Connect To Server Icon ) on the toolbar.

    OPCViewer Connect
    Figure 3: OPC Viewer – Connect

    After successful connection to the OPC server, the icon changes to Successful Connection To TheOPCServer Icon

    OPCViewer Successful Connection
    Figure 4: OPC Viewer – successful connection
    Note Note

    If OPC server is not connected, an offline subscription can be created.

  4. To check the status of the connected OPC server select “View Status” from the server node context menu or click icon ( View Status Icon ) on the toolbar. The Server Status dialog appears:

    OPCViewer Server Status
    Figure 5: OPC Viewer – Server Status
2. Create online subscription in OPC Viewer
  1. To create a subscription, click the right mouse button on the connected OPC server and select “Create Subscription...-> Browse server…” from the context menu. Create Subscription dialog windows appears. Provide the subscription name and click on “Next” button to continue.

  2. Browse a tree view on the left pane (Figure 6) and select requested items. To add an item to a subscription, double click on the item name. When all requested items are added, click on the “Next” button. In the next window, verify the subscription settings (e.g. scanning rate or name) and click on “Done”.

    Note Note

    In the process of the UA Wrapper configuration it is recommended, but not required , that all server items are added to one of the created subscriptions.

    OPCViewer Adding Tags
    Figure 6: OPC Viewer – adding tags
  3. Items added to the subscription appear in the OPC viewer main window (Figure 7).

    OPCViewer Added Items
    Figure 6: OPC Viewer – added items
  4. Finally the subscription must be saved as a session file (*.oses) by choosing “Session -> Save” from the menu.

3. Export address space to a dictionary file using OPC Viewer
  1. Click the right mouse button on the selected OPC server node and select “Browse Items...” from the context menu. Address Space Dictionary Management dialog appears.

    OPCViewer Browse Server Items
    Figure 8: OPC Viewer – Browse server items
  2. Click the "Save" button (Figure 9). In the window that appears, choose "Dictionary files (*.odic)" in the "Save as type" drop-down list and choose location of the *.odic file, where the address space will be saved.

    OPCViewer Saving The Server Address Space InADictionary File
    Figure 9: OPC Viewer – Saving the server address space in a dictionary file
  3. The created session file and dictionary file will be further used by the Address Space Model Designer to automatically create configuration for the CommServerUA.

4. Create new project in UA Address Space Model Designer and choose configuration editor
  1. 1To launch Address Space Model Designer select:

    Start Menu -> All Programs -> CAS -> CommServerUA -> OPC UA Address Space Model Designer

  2. After first launching of the UA Address Space Model Designer, the "Help" panel with version history is being displayed. Click on the "Main" panel to manage the solution content.

  3. To create new project select “Solution -> Add Project ->New” from the context menu (Figure 10).

    UAAddress Space Model Designer Create New Project In The Solution
    Figure 10: UA Address Space Model Designer – Create new project in the solution
  4. Open CommServerUA configuration editor using UA Server menu (figure 11). The default location of this editor is:

    %USERPROFILE%\My Documents\UAAddressSpaceModelDesigner\Sample

    After clicking on the "Open" button the "UA server configuration file" dialog appears. In this walkthrough the configuration is created from scratch using default setting, hence click the "Cancel" button to skip opening a file.

    For more information about using plugins as external configuration editors see UA Server configuration.

    UAAddress Space Model Designer Select Configuration Editor
    Figure 11: UA Address Space Model Designer – Select configuration editor
5. Import OPC DA address space and build the model
  1. To import address space from DA server to UA model click the right mouse button on the context menu of the "Solution -> Project -> Domain" and select "Import -> From OPC DA ...".

    Import FromOPCDA
    Figure 12: Import from OPC DA
  2. After clicking on the "From OPC DA ..." you will be asked to open dictionary file (*odic) created above, so choose the file that you have created in section 3 Then you will be asked to choose session file (*oses), so choose the file that you have created in section 2.

  3. Finally you get the fully functional model with the data bindings. Now you can build the model and get all configuration files required for launching CommServerUA.

  4. To build the model you need to select "Tools -> Build/Verify -> Build Solution" from the menu bar. Before starting the build operation you will be asked to save the solution file, model file, configuration file and *.csv file (if you did not save those files earlier).

Note Note

If there are any problems with Build process, check if all files have correct names and locations and if there are still problems - reset UA Address Space Model Designer options to default values ("Reset" button is in "Tools -> Options").

Now you can use CommServerUA with the configuration similar to your old OPC Classic server.